What is Single-Component Polyurethane with Hardener WP210?
Before using Polyurethane WP210, ensure that the desired surface is primed with a layer of Polyurethane Primer WP200. (100 grams per square meter). For freshly prepared concrete, wait 14 days before applying. The surface must be clean, dry, and free of dust, grease, and any contaminants. The substrate should be cleaned of any loose layers using various mechanical methods, including sandblasting. To achieve better adhesion and higher product quality, the concrete surface should be scratched with a grinder or scraper and then cleaned of dust particles using a broom. An air blow and suction system can also be used at this stage. Before applying Polyurethane WP210, any joints, cracks, and holes on the surface should be repaired. Depending on the size of the hole or crack, you can use different sealants and adhesives produced by Mandana Polymer to repair and seal them. For stone surfaces, ensure that the surface is clean, dry (moisture below 4%), and free of dust, grease, and any other contaminants. The substrate should be cleaned of any loose layers using methods like sandblasting.
How to Use Single-Component Polyurethane with Hardener WP210?
Step 1: Surface Preparation for Applying Polyurethane WP210
Before applying Polyurethane WP210, ensure the surface is primed with a layer of Polyurethane Primer WP200. (100 grams per square meter). For freshly prepared concrete, wait 14 days before applying. The surface must be clean, dry, and free of dust, grease, and contaminants. The substrate should be cleaned of any loose layers using sandblasting or other mechanical methods. To improve adhesion and product quality, use a grinder or scraper to roughen the surface, then sweep away dust particles. An air blow and suction system can be used to assist in cleaning. Before applying Polyurethane WP210, any joints, cracks, and holes on the surface should be repaired with the appropriate sealants and adhesives from Mandana Polymer. For stone surfaces, ensure that the surface is clean, dry (moisture content below 4%), and free from dust, grease, and contaminants. Clean any loose layers using sandblasting or other mechanical methods.
Step 2: Pre-Application Control and Recommendations
Stir the contents of the container gently for 3 minutes and wait for any bubbles caused by mixing to dissipate.
Then apply Polyurethane WP210 to the desired surface using a brush or roller.
Depending on the surface’s size and porosity, the required amount of material can be calculated. 500 grams of Polyurethane covers 1 square meter of a non-porous surface completely. The required amount should be applied in two stages to cover concrete and mortar surfaces.
Application Conditions for Single-Component Polyurethane with Hardener WP210
- Temperature: 10 to 35°C
- Relative Humidity: Maximum 70%
- Re-coating Time: 6 to 24 hours
Note: Avoid applying Polyurethane WP210 in rainy conditions or high humidity (both during application and 24 hours after).
Technical Specifications of Single-Component Polyurethane with Hardener WP210
- Water Penetration Resistance: Resistant
- UV Stability: Stable
- Adhesion to Concrete and Stone: Excellent
- Chemical Resistance: Suitable
Features of Single-Component Polyurethane with Hardener WP210
- Excellent adhesion to concrete and stone surfaces
- Resistant to water penetration
- Enhances the aesthetic appearance of surfaces
- Provides a smooth, uniform coating
- Suitable chemical resistance
- Colorable (pigmentable)
- Can be applied in a single or multiple layers
- Can be used as a main coat or topcoat
- Easy application
- Maintains flexibility in both heat and cold
Applications and Surfaces for Polyurethane WP210
- Strengthening and waterproofing natural and artificial stones
- Bonding cladding stones and tiles
- Filling and repairing cracks in stone surfaces
- Waterproofing tiles and stairs
- Waterproofing wooden surfaces
- Increasing hardness and abrasion resistance in products like wooden flooring
- Protective coating for furniture
Physical and Chemical Properties of Polyurethane WP210
- Application Temperature: 10–30°C
- Coverage per kg: 3-4 square meters
- Application Tools: Trowel (if needed), roller, pump, brush
- Working Time: 30 minutes
- Initial Drying Time: 1 hour
- Final Drying Time: 24 hours
- Reaction to 5% Sulfuric Acid: Inactive
- Reaction to 30% Hydrochloric Acid: Inactive
- Reaction to 30% Household Cleaners: Inactive
- Reaction to Saturated Lime Water: Inactive
- Reaction to 10% Sodium Chloride: Inactive
- Reaction to 4.13 ppm Chloride Ions: Inactive
Storage and Considerations for Polyurethane WP210
- Packaging: 8kg and 16kg containers
- Shelf Life: 12 months in original packaging
- Store in a dry place, away from direct sunlight, water, and rain
- Ideal Storage Temperature: 20 to 30°C
- Do not freeze contents inside the containers
Safety and Protection of Polyurethane WP210
- Avoid direct contact with skin and eyes in liquid form
- Ensure proper ventilation in enclosed spaces during application; this will also aid in better drying
- Always use safety gloves, suitable respiratory masks, and safety goggles during application
- Keep out of reach of children
Standards and Certifications
- Conforms to BS EN14891 (UK Standard)
- Conforms to AS/NZS 4858 (Australia-New Zealand Standard)
- Technical Certificate from the Research Center for Housing and Urban Development
- Only company with factory standards in Iran
- Licensed by the Ministry of Industry, Mine, and Trade
- Certified with ISO 9001, 14001, 18001, IMS